Rear Panel Features
 
 
                          
 
 
     
 
 
 
 
 
 
 
 
HD-SDI Input and Output  
The V-R171-IMD-HDSDI has one HD-SDI input and 
one active loop-through output. Note: No more than 
4 screens should be connected in one loop.
 
 
  
RS-422/485 Serial Interface  
The RS-422/485 ports are used to remotely control 
the IMD or all V-R171-IMD-HDSDI features, using a 
variety of industry standard protocols. (Note: 
Connector/pin-out may need to be adapted 
depending on protocol and controlling device 
used. See pin-out details on page 22.)
 Only one 
connection to either port is needed to control the 
monitor. The second port can be used to loop 
multiple monitors in the same bus. 
 
 
Tally Interface (HD-15)  
Both LED tally and OSD tally can be activated via 
the HD-15 connector by connecting the 
corresponding pin to ground. A variety of external 
devices can be used to perform the contact closure. 
No additional power should be supplied to the HD-
15 port. See pin-out details on page 22. 
 
 
Power Input 
Connect the 12VDC input to the 2-Pin twist lock 
power input connector. Power can be supplied from 
the included power supply, or from a variety of DC 
sources supplying at least 3.0 Amps at 12 Volts. 
 
IMPORTANT: If using a power source other than the 
included power supply, be sure that the polarity of 
the DC input is correct: 
 
 
 
 
 
  
Mounting Slots 
These slots are used when attaching the monitor to 
the optional desktop stand.  