Miranda Camera Co M406-9900-402 Manuale Utente

Pagina di 32
GUIDE TO INSTALLATION AND OPERATION 
Kaleido K2  |  17  
 
Figure 4.4.7.3  MWA-BOC cable adapter 
 
 
4.4.8  Digital Video SD-SDI Input Module (MWI-SDI) 
 
This module provides inputs for four channels of serial digital video. The inputs are on BNC connectors and are 
available on the MWR-4B rear connection module (2). The MWI-SDI accepts a 4:2:2 serial digital video signal in 
either 525 or 625-line format. This input must conform to the SMPTE 259M-C standard.  
 
Make sure the input 4:2:2 cable has a maximum length of 100 m (325’), and that all serial digital video connections 
are point-to-point. For instance, there must be a point-to-point connection between the 4:2:2 IN BNC and the 
source equipment. If a T-connector is used to connect other equipment, the maximum specified cable length is no 
longer valid. 
 
 
 
Figure 4.4.8.1  MWI-SDI  rear connector panel 
 
 
4.4.9  Analog Progressive RGBVH Input Module (MWI-VGA) 
 
This module provides inputs for two channels of VGA-UXGA analog progressive-scan video. The VGA input 
module supports non-interlaced resolutions from 640 to 480 pixels up to 1600 x 1200 pixels at 60 Hz.  The inputs 
are on DE-15P connectors available on the MWR-VGA rear connection module (7). 
 
 
 
Figure 4.4.9.1  MWI-VGA  rear connector panel 
 
Connect RGBHV signals to the DE-15P connectors (refer to figure 4.4.8.2 below for connector pinout).