Seagate ST973451FC Manuale Utente

Pagina di 84
42
Savvio 15K.1 FC Product Manual, Rev. B
   
Figure 13. Air flow
8.3
Drive mounting
Use M3 x .5 metric screws to mount the drive using either side, bottom, or end mounting holes. Select a screw 
length that results in a minimum thread engagement of 0.12 inches when using the side-mounting holes or a 
minimum thread engagement of 0.10 inches when using the bottom or end mounting holes. Use a maximum 
torque of 4.5 +/- .45 in lbs. If the screws are torques above the specified values, threads could be stripped.
Note.
Before mounting the drive in any kind of adapter frame, verify that the drive can meet the shock and 
vibration specifications while mounted in such an adapter frame.
8.4
Grounding
Signal ground (PCBA) and HDA ground are connected together in the drive and cannot be separated by the 
user. The equipment in which the drive is mounted is connected directly to the HDA and PCBA with no electri-
cally isolating shock mounts. If it is desired for the system chassis to not be connected to the HDA/PCBA 
ground, the systems integrator or user must provide a nonconductive (electrically isolating) method of mount-
ing the drive in the host equipment.
Increased radiated emissions may result if you do not provide the maximum surface area ground connection 
between system ground and drive ground. This is the system designer’s and integrator’s responsibility.
Above unit
Under unit
Note.  Air flows in the direction shown (back to front)
           or in reverse direction (front to back)
Above unit
Under unit
Note.  Air flows in the direction shown or
           in reverse direction (side to side)