HP (Hewlett-Packard) Ultrium Drive Manuale Utente

Pagina di 30
13
3 Electrical requirements
PSU requirements
Internal and rack-mounted drives
The drives are specified to operate at 5V±5% and 12V±10%. Any PSU used to power the 
drive must be capable of providing 5V nominal (when the drive pulls 5A on the 5V rail) and 
12V nominal (when the drive pulls 2A on the 12V rail). HP recommends a 10% buffer when 
selecting a power supply source capable of delivering the amperage and power required.
* The current values are calculated based on constant power and minimum power supply voltage.
Power consumption
SCSI Drives
FC Drives
Specification
5V
12V
5V
12V
Maximum voltage
5.25V
13.2V
5.25V
13.2V
Minimum voltage
4.75V
10.8V
4.75V
10.8V
Maximum steady-state current
4.75*A
1.0A
4.75*A
1.0A
Maximum transient current
4.75*A
2.0A
4.75*A
2.0A
Maximum steady-state power
22.5W
12W
17.5W
12
W
Maximum transient power
22.5W
24W
22.5W
24W
Maximum noise/ripple
150 mVpp 150 mVpp 150 mVpp 150 mVpp
Internal Drives
External Drives
Power Requirements
<40W
100–240 VAC 50/60 Hz 0.8A max.
5V DC
3.0A typical (4.5A max.)
12V DC
0.8A typical (2.0A max.)
SCSI Drives
FC Drives
Activity
Average
Peak
Average
Idle
15.8W
15.8W
TBD
Load
18.1W
32.3W
TBD
Write
30.2W
35.3W
TBD