HP (Hewlett-Packard) Ultrium Drive Manuale Utente

Pagina di 30
Environmental
18
Dynamics
Noise
Airflow
HP Ultrium drives require forced airflow from front to back.
Parameter
Specification
Operating sine vibration
0.31G pk 5–500 Hz @ 1 octave/min with 15 min dwell at peak 
resonance
Operating random vibration
0.31G rms 5–500 Hz 0.000194 g
2
/Hz
Operating shock
5G 3 ms half-sine (no performance change)
2G 11 ms half-sine (no performance change)
8G 11 ms half-sine (no data loss)
Pulse rate: 0.1 Hz
Non-operating sine vibration
1.0G pk 5–500 Hz @ 1 octave/min with 5 min dwell at peak 
resonance
Non-operating random vibration 2.41G rms 5–500 Hz
Non-operating shock
90G 3 ms half-sine (no damage)
30G 26 ms trapezoidal (no damage)
Transportation sine vibration
0.5G pk 5–200–5 Hz @ 1 octave/min with 5 min dwell at peak 
resonance
Transportation random vibration 1.47G rms 5–200 Hz
Package drop
0.91m (36 in)
Parameter
Specification
Operating acoustic noise <5.0 bel sound power
Parameter
Specification
Airflow (operating and non-operating) 0.17 m
3
/min (6 cu ft/min) at 35ºC ambient operation, rising to 
0.23 m
3
/min (8 cu ft/min) for up to 40ºC ambient operation