Fujitsu MCM3130SS Manuale Utente

Pagina di 170
 
7.5  Timing Rule 
C156-E228-02EN 7-17 
Table 7.7  Timing specifications (3 of 3) 
No. Name 
Standard 
Timing 
specification 
17 
Transfer Period 
50 ns 
In synchronous data transfer mode, the minimum time 
(minimum repetition time) from the leading edge of an 
REQ signal to the leading edge of the next REQ signal 
or from the leading edge of an ACK signal to the 
leading edge of the next ACK signal.  The actual value 
is defined using a SYNCHRONOUS DATA 
TRANSFER REQUEST message exchanged between 
the INIT and TARG. 
 
Table 7.8  SCSI BUS Timing specifications 
Synchronous data transfer mode 
No. Name 
Fast-20 Fast-SCSI SCSI-1 
Asynchronous 
data transfer 
mode 
1 Arbitration 
Delay 
2.4
µ
s 2.4
µ
s 2.4
µ
s 2.4
µ
Bus 
Clear 
Delay 
800ns 800ns 800ns  800ns 
Bus Free Delay 
800ns 
800ns 
800ns 
800ns 
Bus 
Settle 
Delay 
400ns 400ns 400ns  400ns 
Cable Skew Delay 
3ns 
4ns 
4ns 
4ns 
Data Release Delay 
400ns 
400ns 
400ns 
400ns 
Receive 
Assertion 
Period 
11ns 22ns 70ns 
–– 
Receive Hold Time 
11.5ns 
25ns 
25ns 
–– 
Receive 
Negation 
Period 
11ns 22ns 70ns 
–– 
10 
Receive Setup Time  
6.5ns 
15ns 
15ns 
–– 
11 
Reset 
Hold 
Time 
25ns 25ns 25ns  25ns 
12 
Selection Abort Time 
200ns 
200ns 
200ns 
200ns 
13 
Selection 
Time-out 
Delay 
250ns 250ns 250ns  250ns 
14 
System 
Deskew 
Delay 
15ns 20ns 45ns  45ns 
15 Transfer 
Period 
during 
Synchronous Data Transfer Phases 
50ns 100ns 200ns 
–– 
16 
Transmit Assertion Period  
15ns 
30ns 
80ns 
–– 
17 Transmit 
Hold 
Time 
16.5ns 
33ns 
53ns 
–– 
18 
Transmit Negation Period 
15ns 
30ns 
80ns 
–– 
19 
Transmit Setup Time 
11.5ns 
23ns 
23ns 
––