Fujitsu MCM3130SS Manuale Utente

Pagina di 170
Installation Requirements 
3-4 C156-E228-02EN 
3.1.4 Air flow 
It is recommended that this optical disk drive be installed in a fanless cabinet.  
However, if the power supply is included in the same cabinet, the “Temperature 
Conditions” in 3.1.2 must be met.  Furthermore, we recommend that the speed of 
air drawing in by the device from the left side of the cartridge loading slot in the 
front panel dose not exceed 0.3m/s for MCM3064SS or MCM3130SS, and dose 
not exceed 0.1m/s for MCP3064SS or MCP3130SS.  If this unit is to be used as a 
built-in drive, the system fan (if one is supplied) must meet the same conditions. 
3.1.5 Air cleanliness 
The air cleanliness in the device environment is expressed by the number of dust 
particles per unit area.  Fujitsu recommends using the optical disk drive in the 
environment of class 5 million or less particle level.  (Class 5 million:  This means 
there are 5 million dust particles of 0.5 
µ
m diameter or larger per cubic foot.  This 
is equivalent to 0.15 mg/m
3
.) 
3.2  Mounting Requirements 
3.2.1 Outer dimensions 
Figures 3.2 to 3.3 show the outer dimensions of the optical disk drive and the 
positions of the mounting holes.