Interface
5-74
C141-E050-02EN
Note:
For transfer of a sector of data, the host needs to read Status register (X’1F7’) in order to
clear INTRQ (interrupt) signal. The Status register should be read within a period from the
DRQ setting by the device to 50 
µ
s after the completion of the sector data transfer.  Note that
the host does not need to read the Status register for the first and the last sector to be
transferred.  If the timing to read the Status register does not meet above condition, normal
data transfer operation is not assured guaranteed.
When the host issues the command even if the drive requests the data transfer (DRQ bit is
set), or when the host executes resetting, the device correct operation is not guaranteed.
5.4.3 Commands without data transfer
Execution of the following commands does not involve data transfer between the
host and the device.
• 
RECABLIBRATE
• 
SEEK
• 
READY VERIFY SECTOR(S)
• 
EXECUTE DEVICE DIAGNOSTIC
• 
INITIALIZE DEVICE PARAMETERS
• 
SET FEATURES
• 
SET MULTIPLE MODE
• 
IDLE
• 
IDLE IMMEDIATE
• 
STANDBY
• 
STANDBY IMMEDIATE
• 
CHECK POWER MODE
• 
SECURITY ERASE PREPARE
• 
SECURITY FREEZE LOCK
• 
FLUSH CACHE
Figure 5.6 shows the protocol for the command execution without data transfer.