  General Purpose Log Directory     
Byte Descriptions 
0-1 
General Purpose Logging Version 
Number of sectors in the log at log address 01h (7:0) 
Number of sectors in the log at log address 01h (15:8) 
Number of sectors in the log at log address 02h (7:0) 
Number of sectors in the log at log address 02h (15:8) 
…  
256 
10h sectors in the log at log address 80h 
257 
00h sectors in the log at log address 80h 
…  
510-511 
Number of sectors in the log at log address FFh 
 
The value of the General Purpose Logging Version word is 0001h.     
 
The logs at log addresses 80-9Fh shall each be defined as 16 sectors long. 
 
11.8.43.2  Extended Comprehensive SMART Error log     
 
The fpllowing table defines the format of each of the sectors that comprise the Extended Comprehensive 
SMART error log.    The size of the Extended Comprehensive SMART error log is 64 sectors.    Error log data 
structures shall include UNC errors, IDNF errors for which the address requested was valid, servo errors, write 
fault errors, etc. Error log data structures shall not include errors attributed to the receipt of faulty commands 
such as command codes not implemented by the device or requests with invalid parameters or invalid 
addresses.  
 
All 28-bit entries contained in the Comprehensive SMART log, defined under section 11.8.42.6.3, shall also be 
included in the Extended Comprehensive SMART error log with the 48-bit entries. 
 
Extended Comprehensive SMART error log   
Byte 
First sector 
Subsequent sectors 
SMART error log version 
Reserved 
1 Reserved 
Reserved 
Error log index (7:0) 
Reserved 
Error log index (15:8) 
Reserved 
4-127 
First error log data structure 
Data structure 4n+1 
128-251 
Second error log data structure 
Data structure 4n+2 
252-375 
Third error log data structure 
Data structure 4n+3 
376-499 
Fourth error log data structure 
Data structure 4n+4 
500-501 
Device error count 
Reserved 
502-510 Reserved 
Reserved 
511 
Data structure checksum 
Data structure checksum 
n is the sector number within the log. The first sector is sector zero 
 
11.8.43.2.1  Error log version 
 
The value of the SMART error log version byte is 01h. 
 
11.8.43.2.2  Error log index 
 
The error log index indicates the error log data structure representing the most recent error. If there have been 
no error log entries, the error log index is cleared to zero.    Valid values for the error log index are zero to 255.