7. POWER REQUIREMENTS   
7.1 
Supply Voltage 
 
   Allowable voltage            
 3.3V + 5% 
   Allowable noise/ripple        
 70 mV p-p or less 
 
(note 1)    When DC power is interrupted,+3.3V voltage drop must be greater than or equal 0V. 
 
7.2 Power Consumption 
Average(note 1)   
                                                 
MK3006GAL/MK6006GAH/MK4006GAH 
    Start                                 
1.2 W Maximum 
  Seek (note 2)           
1.1 W Typical 
  Read / Write(note 3)     
1.1 W Typical 
  Active idle (note 4 )     
 0.4 W Typical 
    Low power idle (note 5) 
  0.3 W Typical 
  Stand- by (note 6)       
 0.12 W Typical 
  Sleep 
 0.07 W Typical 
 
(note 1)    Under normal condition ( 25oC, 101.3 kPa ( 1,013 mb ) ) and 3.3V + 0%.   
(note 2)    The seek average current is specified based on three operations per 100 ms.   
(note 3)    The read/write current is specified based on three operations of 63 sector read/write per 100 ms. 
(note 4)    Motor is rotating at normal speed but none of Read, Write or Seek is executed. 
(note 5)    Motor is rotating at normal speed but heads are unloaded on the ramp. 
(note 6)    Motor is not rotating and heads are unloaded on the ramp. 
 
 
7.3  Energy Consumption Efficiency 
Energy consumption efficiency             
(W/GB) 
Classification 
  Power consumption at Low power idle / Capacity 
MK3006GAL 
 
0.010 
 
MK4006GAH 0.0075 
MK6006GAH  
0.005 
 
Energy consumption efficiency is calculated in accordance with the law regarding efficiency of energy 
consumption 
:Energy saving law,1979 law number 49. 
Calculation of Energy consumption is dividing consumed energy by the capacity. 
The consumed energy and capacity shall be measured and specified by the Energy saving low.