7. POWER REQUIREMENTS
7.1 Supply Voltage
Allowable voltage
5V + 5%
Allowable noise/ripple
100 mV p-p or less
7.2 Power Consumption
Average (note 3)
MK1032GAX
Start
4.5W Peak,Maximum
Seek (note 4)
2.4W Typical
Read / Write(note 5)
2.0W Typical
Active idle (note 1)
0.85W Typical
Low power idle (note 6)
0.65W Typical
Stand- by (note 2)
0.18W Typical
Sleep
0.1W Typical
(note 1) Motor is rotating at normal speed but none of Read, Write or Seek is executed.
(note 2) Motor is not rotating and heads are unloaded on the ramp.
(note 3) Under normal condition ( 25oC, 101.3 kPa ( 1,013 mb ) ) and 5V + 0%.
(note 4) The seek average current is specified based on three operations per 100 ms.
(note 5) The read/write current is specified based on three operations of 63 sector read/write per 100 ms.
(note 6) Motor is rotating at normal speed but heads are unloaded on the ramp.
7.3 Energy Consumption Efficiency
Energy consumption efficiency Average(W/GB)
Classification
Power consumption at Low power idle / Capacity
MK1032GAX
0.0055
E
Energy consumption efficiency is calculated in accordance with the law regarding efficiency of energy
consumption
:Energy saving law,1979 law number 49.
Calculation of Energy consumption is dividing consumed energy by the capacity.
The consumed energy and capacity shall be measured and specified by the Energy saving low.
consumption
:Energy saving law,1979 law number 49.
Calculation of Energy consumption is dividing consumed energy by the capacity.