11.3.3 Signal Treatment 
Driver types and requirements for the signal pull- up and down are as follows. Resistor requirement is minimum for the 
host. - IO16 is pulled up in the drive with certain value so that the Vol is obtained to run with a host that has large value of 
pull up resistor.    - CS0    and - CS1 are also pulled up for better noise immunity. 
 
Table 11.3-2  Signal treatment 
    SIGNAL 
Driven by 
TYPE 
By host 
By drive 
- RESET 
host 
TP 
 
10kΩPU 
 DD 0:15 
bi-direction
TS
 DMARQ drive  TS
5.6 
Ω PD
- DIOR 
host TS
-DMARDY 
 
   
HSTROBE 
 
   
- DIOW 
host TS
STOP   
   
 IORDY 
drive 
TS
4.7 k 
Ω PU
-DDMARDY 
 
   
DSTROBE 
 
   
 CSEL 
host GND
10 
Ω PU 
- DMACK 
host TP
 INTRQ drive TS
10 
Ω PD
- IOCS16 
drive 
OD
1.0 k 
Ω PU
1.2 k 
Ω PU 
 DA 0:2 
host TP
- PDIAG/
drive TS
10 
Ω PU 
- CS0  - CS1
host TP
- DASP 
drive 
OD
10 k 
Ω PU 
TP = Totem Pole, TS = Tri-State, PD = Pull Down, PU = Pull-Up, OD = Open Drain