Laser LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Appendix E: Troubleshooting Guide 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 209 of 221 
Revision A (Sep 2007) 
communications. 
 
 
much better noise immunity than RS-232.  
USB to RS-422 converters are 
commercially available. 
 
 
Quality Factor/Valid Measurements 
 
Poor Quality Factor on round 
product 
Product not well guided 
Check guiding and product vibration.  
Try to keep the laser spot within +/- 10% 
percent of the product diameter.  This is 
more critical on clear or shiny products.   
 
If the product begins to vibrate at higher 
line speeds, guide rollers may need to 
be placed closer to the laser spot. 
 
Poor Quality Factor on product 
with liquid/coolant 
Too much coolant on 
product 
 
 
Steam or spray in the beam 
path 
 
 
 
Quick-Change Window 
LaserSpeed gauges can measure on 
thin coatings of liquid but may not work 
well on thick or flowing coatings. 
 
Install a fan to blow steam away from 
the beam path to see if the QF 
improves.  Purchase and install a beam 
purge on the gauge. 
 
Remove and inspect the Quick-Change 
Window.  Clean with a clean cloth.  
Replace the window if it's scratched or 
damaged. 
 
Valid LED is not illuminated 
 
-- or -- 
 
The gauge is not measuring 
Something is affecting the 
laser beams 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Check that the sensor is emitting two 
laser beams and that they are elliptical 
in shape.  Measure the laser power if 
possible and report value to Beta 
LaserMike. 
 
Result of Laser beam inspection: 
Result A
: The sensor emits two laser 
beams but they are not elliptically 
shaped. 
Action: 
1.  Check quick change window for 
contamination 
2.  Clean or exchange quick change 
window. 
 
Result B: The sensor emits two laser 
beams and they elliptically shaped. 
1.  Check distance to the product and