Laser LS8000-3 Manuale Utente

Pagina di 221
LaserSpeed 8000-3 Instruction Handbook
 
Interfacing with the LS8000-3 
 
 
Part No. 93463 / Drawing No. 0921-01561 
Page 53 of 221 
Revision A (Sep 2007) 
 
Shutter Control (Pin 17)  
All Class 3B laser products are required to have a shutter to terminate the 
laser beams before exiting the product.  The LS8000-3 uses a spring-loaded 
rotary solenoid as a laser shutter. The spring-loaded action ensures that when 
power is not applied to the shutter circuit, the shutter remains closed. 
Note:   To open the shutter, connect the shutter control pin (Pin 17) to 
ground (Pin 11, 19, or 21). 
 
Panel Cutout
for Keyswitch
0.42in
[10.7mm]
0.50in
[12.7mm]
Shutter Closed
Shutter Open
Shutter Interlock Examples 
 
Length Reset Input (Pin 18) 
This is an optically isolated input that can be used to externally control the 
Length Reset feature of the LS8000-3.  The input requires a voltage high (5 to 
24V) to activate.  The input level should be the same as the voltage connected 
to the User V
IN
 input (Pin 20) or 5V if there is nothing connected to the User 
V
IN
 input. 
The Length Reset input is used to reset the current length count to zero.  This 
is the length that is reported over RS-232, RS-422, and Ethernet.  The pulse 
outputs are not affected by this input. 
This can also be accomplished through the "R" command of the serial 
command set (see the 
Communication Protocol
 section) for more information 
on interfacing with serial commands.