5.1.4 
Elevator Board / Floor Hardware Test 
This testing sequence will allow you to check activation of individual relays on the elevator control 
board(s) and will confirm communication between the 1838 circuit board and the elevator control 
board(s). 
 
1. Press 
* 7 7 and enter the four-digit master code _ _ _ _ (beep). 
2.  Enter the elevator shaft number _ (1, 2, 3 or 4) then press * (beep). 
3.  Enter the two-digit floor number _ _ , then press * (beep). 
4.  The relay LED on the elevator control board that represents the floor number entered will 
turn ON for approximately 1 second. 
5.  To check other floor relays, repeat steps 2 and 3. 
6.  When complete with the testing, press 0 # TOGETHER to end this testing sequence. 
NOTE:  This program test sequence will automatically end itself if no keypad inputs are 
detected after approximately 30 seconds. 
 
Refer to the Elevator Control board installation manual for more information on trouble 
shooting the elevator control boards
 
 