Fujitsu CA97232-0014-01EN Manuale Utente

Pagina di 13
Supplement for Embedded MegaRAID SATA User
’s Guide 
 
 
¾
  “4.9.2 Checking Array Controller Status” (page 98)   
 
When using driver version of V10.xx or later, As for “4.9.2 Checking Array Controller Status” on page 
98, include the information as follows;   
 
Item 
Category 
Description 
BIOS version 
Version number of the expansion ROM BIOS for the 
array controller. 
Adapter 
BIOS build time 
BIOS build time of the expansion ROM BIOS for the 
array controller. 
 
 
 
 
¾
  “5.1.1 Message and Error Handling” (page 108)   
 
POST messages and handling of the “5.1.1 Message and Error Handling” on page 108 is partially 
modified as follows;   
 
Description  Detecting a logical drive being rebuilt 
Message 
PORT is Rebuilding State 
WARNING : Array(s) in Degraded Mode!!! 
 
XX Virtual drive(s) Configured. 
Array#     Mode         Stripe Size    No Of Stripes  DriveSize  Status 
00         RAID 1        64KB             02          XXXXXXMB  
Degraded 
Meaning 
The hard disc x connected to the port x is being rebuilt, and the logical drive is 
critical (degraded). 
To start up SATA Setup Utility, press the [Enter] key or the [Ctrl]+[M]keys. 
To pass POST, press any other key. 
Action 
For expansion ROM BIOS A.05.09061342R: 
POST halts waiting for key-in. 
To pass POST and invoke OS, press any key other than the [Enter] key or the 
[Ctrl]+[M]keys. 
 
For expantion ROM BIOS A.06.05071459R: 
No action is required. 
 
11 / 13