Omega 1002 Manuale Utente

Pagina di 48
 
 
The A/D trigger logic can initiate an A/D conversion upon an 
external trigger. Valid external trigger signals must be TTL compatible 
and meet minimum pulse width requirements. The requirements are shown 
below: 
 
 
 
 
 
t
re
 
t
du
External trigger 
 
 
Symbol Name  Minimum 
Maximum
T
du
 
Duration time 
40ns 
 
T
re
 
Recover time 
100ns 
 
 
 
Note: The OME-PCI-1002 is designed only for time sensitive triggers 
(trigger is dependent only on the time of the falling edge of 
signal). For a level sensitive external trigger (trigger is dependent 
on the level of the input signal), the user can build the following 
external circuit the OME-PCI-1002: 
 
 
 
 
 
 
 
DAC 
OME-PCI-
1002 D/O
 
Input Signal
 
Comparator   
TTL buffer
 
External 
Trigger
 
 
 
 
 
 
 
 
37