NEC PD17062 Manuale Utente

Pagina di 296
281
µ
PD17062
22.4   BUILT-IN MACRO INSTRUCTIONS
The following macro instructions are built in the 17K series assembler (AS17K).  For details, refer to the
assembler user’s guide.
Legend
flag n
: FLG-type symbol
< >
: An operand enclosed in < > is optional.
Mnemonic
Operand
Operation
n
Built-in
SKTn
flag 1, … flag n
if (flag 1) to (flag n) = all “1”, then skip
 n 
 4
SKFn
flag 1, … flag n
if (flag 1) to (flag n) = all “0”, then skip
 n 
 4
SETn
flag 1, … flag n
(flag 1) to (flag n) 
 
1
 n 
 4
CLRn
flag 1, … flag n
(flag 1) to (flag n) 
 
0
 n 
 4
NOTn
flag 1, … flag n
if (flag n) = “0”, then (flag n ) 
 
1
 n 
 4
if (flag n) = “1”, then (flag n) 
 0
INITFLG
<NOT>flag 1,
if description = NOT flag n, then (flag n ) 
 
0
 n 
 4
… <<NOT>flag n>
if description = flag n, then (flag n) 
 1
BANKn
(BANK) 
 
n
 n 
 2
macro