4.2 Setting of Stack Bank Selection (SBS) Register
Use the stack bank selection register to switch between the Mk I mode and Mk II mode.  Figure 4-1 shows the format
of the stack bank selection register.
The stack bank selection register is set using a 4-bit memory manipulation instruction.  When using the Mk I mode, be
sure to initialize the stack bank selection register to 100
×B
Note
 at the beginning of the program.  When using the Mk II mode,
be sure to initialize it to 000
×B
Note
.
Note Set the desired value for 
×.
Figure 4-1. Format of Stack Bank Selection Register
Caution
SBS3 is set to 1 after RESET input, and consequently the CPU operates in the Mk I mode.  When using
instructions for the Mk II mode, set SBS3 to 0 and set the Mk II mode before using the instructions.