NEC PD78P214 Manuale Utente

Pagina di 487
393
Chapter 15   Reset Function
15
Fig. 15-3  Timing Charts for Reset Operation
(a)  For 
µPD78213
(b)  For 
µPD78214
15.2  NOTE
When resetting the system at power-on, do not set the RESET signal high immediately after the supply voltage
reaches the specified level.  Keep the signal low until oscillation has settled.
Reset period
Hi-Z
Hi-Z
Hi-Z
Hi-Z
Hi-Z
Hi-Z
Address
(output)
Program
(input)
RESET
(input)
ASTB (output)
A8-A19
(output)
AD0-AD7
RD (output)
WR output
Other I/O ports
Instruction execution period after reset
Reset period
Hi-Z
Hi-Z
Hi-Z
RESET
(input)
ASTB (output)
P60-P63
(output)
Other I/O ports
Instruction execution period after reset