Appendix – Re-Assembly Procedure 
 
The positive voltage for F1 is located on 
A24-TB1-2 (labeled SW OUT).  The 
negative voltage for F2 is located on A24-
TB1-3 (labeled DC- OUT).  Use a #2 
Phillips screwdriver with 50mm (2”) shaft to 
tighten connections to 2.0 N-m (17.5 in-
lbs).   
4
 
 
 
 
Figure 25: Dual Gate Drive PCB 
7.  Connect the interface cable labeled J5A 
coiled-up on the Line Side Converter to the 
corresponding connector J5 in the Motor 
Side Inverter enclosure.  Figure 26 
indicates proximity to the cabinet blower. 
 
 
 
6
PCB power terminals at the Field Control 
Module (A24). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 2 : Motor Field Supply (A24) 
6.  Next, connect the Gate Driver Interface 
Cables to the Dual Gate Driver PCB on the 
Motor Side Inverter enclosure.   
Connect the cable labeled JG1 to the plug 
labeled JG1 on the Dual Gate Driver PCB. 
Connect the cable labeled JG2 to the plug 
labeled JG2 on the Dual Gate Driver PCB. 
Connect the cable labeled JG3 to the plug 
labeled JG3 on the Dual Gate Driver PCB. 
Connect the cable labeled JG4 to the plug 
labeled JG4 on the Dual Gate Driver PCB. 
Connect the cable labeled CT5 to the 
respective plug labeled CT5 located above 
the Dual Gate Driver PCB. 
In Addition, connect the cable labeled CT6 
to the respective plug labeled CT6 located 
above the Dual Gate Driver PCB. 
See Figure 2  for reference. 
 
 
 
 
 
CT5
CT6 
JG2
JG1
JG4 
power 
supply
JG3 
DC 
bus
Cable assembly is in 
converter cabinet 
 
 
 
 
 
 
DC- OUT (F2-) 
SW OUT (F1+) 
TB1
J1 
J3 
 
 
 
 
 
 
Plug inverter 
cabinet fan in here 
Fan cable J5A
 
 
 
 
 
 
 
 
 
Figure 2 : Cooling Blower Control 
8.  Next, connect the wires for the Motor 
Voltage Feedback.  The cables wires are 
coiled-up in the Motor Side Inverter 
enclosure.  Dress and secure the cable 
from the Motor Side Inverter to the Line 
Control and Voltage Feedback PCB (A8) in 
the Line Side Converter enclosure.   See 
Figure 20 for location of PCB A8.  Connect 
the wires by the following table torqued to 
0.23-0.28 N-m (2-2.5 in-lbs).  For location 
of connections, refer to Figure 27. 
Wire Number 
A8 connections 
19 TB2-1 
16 TB2-2 
25 TB2-3 
26 TB2-4 
 