Section 3   Connection Procedures 
 
 
Rev. 1.00  Nov. 18, 2008  Page 9 of 18 
 
 
REJ10J1937-0100
 
3.1.3 
Connecting Common User-System Interface Adaptor Cable (Board Unit) to 
EV-Chip Unit 
WARNING
 
   Observe the precautions listed below.  Failure to do so  
will result in a FIRE HAZARD and will damage the user  
system and the emulator product or will result in 
PERSONAL  INJURY.  The USER PROGRAM will be LOST.   
 
1.Always switch OFF the user system and the emulator 
 
   product before the USER SYSTEM INTERFACE CABLE  
 
   is connected to or removed from any part.  Before  
 
   connecting, make sure that pin 1 on both sides are  
 
   correctly aligned.  
 
2.The user system interface cable dedicated to the  
 
   emulator must be used.   
1.  Make sure the user system and emulator are turned off. 
2.  Align the connectors on the common user-system interface adaptor cable (board unit) with 
those on the EV-chip unit according to their numbers (figure 4). 
3.  Adjust the height of the spacer attached to the common user-system interface adaptor cable 
(board unit) with the user system.