CHAPTER 44: 12-BIT A/D CONVERTER 
 
 
5. Operation 
 
FUJITSU SEMICONDUCTOR LIMITED 
CHAPTER
 : 12-BIT A/D CONVERTER 
FUJITSU SEMICONDUCTOR CONFIDENTIAL 
81 
  About the setting of the compare value of the compare match activation 
When the generation interval of the compare match is shorter than the conversion time of A/D in the same 
activation channel that does the compare match activation, the compare match generated while the A/D 
conversion is operating is disregarded. 
Figure 5-5 When the generation interval of the compare match is shorter than the conversion 
time of A/D in the same activation channel 
Compare value 0
(ADCOMP0)
Count value
time
ADTCS0.SEL1,SEL0
Compare match 
activation request 0
00
B
A/D activation request
A/D conversion completion
Reactivation with an activation request does not occur
during A/D activation request on the same activation channel.
 
 
Moreover, when the generation interval of the compare match is shorter than the conversion time of A/D in 
between the activation channels that activate the same A/D converter, the A/D conversion start by the 
activation request generated while the A/D conversion is operating is kept waiting. In this case, The A/D 
conversion does not start according to the intended timing. The start of the A/D conversion is delayed more 
than the intended timing.   
Figure 5-6 When the generation interval of the compare match is the shorter than the 
conversion time of A/D in between the activation channels 
Compare value 0
(ADCOMP0)
Count value
time
Compare match 
activation request 0
ADTCS1.SEL1,SEL0
10
B
A/D activation request
A/D conversion completion
Compare match 
activation request 1
ADTCS0.SEL1,SEL0
01
B
A/D activation request
A/D conversion completion
A/D activation
A/D activation with an activation
request 0 is kept waiting because
A/D conversion with an activation 
request 1 is in process.
Compare value 1
(ADCOMP1)
 
 
MB91520 Series
MN705-00010-1v0-E
1884