Fujitsu FR81S Manuale Utente
CHAPTER 17: PPG
4. Registers
FUJITSU SEMICONDUCTOR LIMITED
CHAPTER
: PPG
FUJITSU SEMICONDUCTOR CONFIDENTIAL
36
TSELii [6:0]
Activation trigger selection
0
1
0
0
1
1
1
Internal trigger (EN39) selected
0
1
0
1
0
0
0
Internal trigger (EN40) selected
0
1
0
1
0
0
1
Internal trigger (EN41) selected
0
1
0
1
0
1
0
Internal trigger (EN42) selected
0
1
0
1
0
1
1
Internal trigger (EN43) selected
0
1
0
1
1
0
0
Internal trigger (EN44) selected
0
1
0
1
1
0
1
Internal trigger (EN45) selected
0
1
0
1
1
1
0
Internal trigger (EN46) selected
0
1
0
1
1
1
1
Internal trigger (EN47) selected
0
1
1
1
1
1
0
16-bit reload timer 0 selected
0
1
1
1
1
1
1
16-bit reload timer 1 selected
1
0
0
0
0
0
0
External trigger 0 selected
1
0
0
0
0
0
1
External trigger 1 selected
1
0
0
0
0
1
0
External trigger 2 selected
1
0
0
0
0
1
1
External trigger 3 selected
1
0
0
0
1
0
0
External trigger 4 selected
1
0
0
0
1
0
1
External trigger 5 selected
1
0
0
0
1
1
0
External trigger 6 selected
1
0
0
0
1
1
1
External trigger 7 selected
1
0
0
1
0
0
0
External trigger 8 selected
1
0
0
1
0
0
1
External trigger 9 selected
1
0
0
1
0
1
0
External trigger 10 selected
1
0
0
1
0
1
1
External trigger 11 selected
Note:
A trigger input to PPG is selected.
On selected PPG, the PPG will be activated when the edge selected by the trigger input edge selection bits
(PCN:EGS1, RGS0) is detected upon the selected activation trigger.
MB91520 Series
MN705-00010-1v0-E
577