Omega LDP-126 Manuale Utente

Pagina di 18
 Page : 15
     master
slave
124-C0                                
124-C1
126-C2
144-C0 
144-C1
146-C2
LDP-124-C
YES
NO
YES
NO
LDP-126-C
NO
YES
NO
YES
LDP-144-C
YES
NO
YES
NO
LDP-146-C
NO
YES
NO
YES
COMPATIBILITY TABLE AMONG MASTER-SLAVE
APPENDIX 2: TIME-NET CONFIGURATION AND CONNECTIONS.
It is advisable to make the TIME-NET connections as follows:
MASTER
  
 
SLAVE
SLAVE
SLAVE
SLAVE
   
SLAVE
Don’t connect RS-422 (JP1) line termination.
1
4
3
2
Transmitter
     Unit
Receiver                         
   Units
Connect RS-422 (JP1)
line termination.
Note
Shielded twisted-pair cable, must be used for connections.
n  (maximum 32 units)
MASTER
SLAVE
9
1
5
6
9
5
6
 shield
shield
To other slaves 
To other slaves
Don’t connect the cable shield
to the receiver units (slaves).
1