Dialogic 6.2 Manuale Utente

Pagina di 441
Enabling the R2 Protocol
November 2009
345
pulseToneDuration
Duration of a backward pulse 
signal (Ref. ITU Q.442).
ms
Typically [100 - 200]
Outbound MFC Timers
forwardToneMaxOnTime
Time associated with the outbound 
“T1” timer that supervises the 
interval between start of a forward 
tone and cessation of the forward 
tone (Ref. ITU Q.476).
Seconds This is typically in the 
range [12-18], but refer 
to network 
specification.
forwardToneMaxOffTime
Time associated with the outbound 
“T2” timer that supervises the 
interval when no forward tones are 
sent. This interval consists of the 
period waiting for the backward 
tone to stop, as well as any 
additional time needed for the next 
forward tone to be known. 
Seconds Typically set to > 24
(Q.476), but refer to 
network specification.
forwardGroup2MaxOnTime
Not used.
Seconds Not used.
Protocol Control
dnisTimeOutAction
Not used.
Not used.
Protocol State Transition Specification
Each of the following is an array of length 16. Element zero is invalid and elements 1-15 correspond to 
R2 MF signals 1-15. These allow the Call Setup Service Pack software to construct the proper state 
transition tables for a given trunk.
Forward Channel Signal Definitions
endOfDNIS
Signal end of DNIS pulsing; NOT 
defined in some variants.
endOfANI_Available
Signal end of ANI identification 
when ANI digits are available.
InfoNotAvailable
Indicates that ANI information is 
restricted. There is usually no need 
to distinguish from signal 
“aniRequestNotAccepted”.
aniCategoryDefault
Default Group 1 category. Used if 
category is not specified in a given 
call request.
Table 19.   R2 MFC Inter-register Signaling Parameters (Continued)
Name
Description
Units
Range