Premier Mounts CDM-600 Manuale Utente

Pagina di 250
CDM-600 Satellite Modem 
Revision 7 
Remote Control  
MN/CDM600.IOM 
15–7 
Modem Alarms 
Relay outputs (Tx, Rx & unit faults) 
Demodulator I & Q test outputs (constellation) 
Demodulator Rx Signal Level output (0 to 2.5 volts) 
External carrier off input 
15-pin D-sub (male) 
IDR BWA Outputs 
4 backward alarm Form C relay outputs 
 
15-pin D-sub (female) 
Remote Control 
RS-232 or RS-485 modem control and monitoring 
9-pin D-sub (male) 
ADPCM Audio Interface 
2 audio channels, each occupying 32 kbps bandwidth as part of IDR 
overhead or as a 64 kbps primary data rate option. 
600 
Ω balanced – 0 dBm0 nominal, -6 to +8 dB, 2 dB steps 
9-pin D-sub (female) 
Auxiliary Serial 
RS-232 link to other modem in 1:1 pair, via CRS-150 
USB Type B Socket 
 
15.4 
Automatic Uplink Power Control 
 
Operating Mode 
Requires Closed Network Framed mode (EDMAC, D&I++, or ESC++) for transport of Eb/No information 
from remote modem (EDMAC can be enabled or disabled) 
Target Eb/No range 
0 to 9.9 dB at remote demod (default is 4.0 dB) 
Max AUPC range  
0 to 9 dB (default is 3 dB) 
Monitor functions 
Remote demod Eb/No  
Tx power level increase 
(front panel or via remote control interface) 
 
 
15.5 Framing 
Summary 
 
 
Transparent 
EDMAC 
IDR 
IBS 
D&I 
D&I++ 
ESC++ 
Overhead 
added 
None 
To 2 Mbps: 
1.5%  
Above 2 Mbps: 
1.5% 
(see Note 2) 
Fixed 96 kHz 
1/15 of front 
panel data rate 
1/15 of front 
panel data rate 
Terrestrial is T1 
or E1 
1/45 of front 
panel data 
rate 
Terrestrial is 
T1 or E1 
Variable: 
between 
11.76% at  
64 kbps 
to 1.58% 
above  
7 Mbps 
Available 
data rates 
and format 
All rates and 
formats 
All rates and 
formats 
T1, E1, T2 and 
E2; all formats 
64 to 2048 
kbps only; all 
formats 
Specific 
multiples of 64 
kbps only 
Any multiple 
of 64 kbps, up 
to n = 24. 
All rates 
and formats 
Overhead 
components 
None Remote 
control 
link between 
modems’ 
processor 
plus AUPC 
EIA-422 ESC 
(8 kbps) 
EIA-422 ESC 
 (64 kbps or 2 
audio links) 
4 BW  alarms 
EIA-232 Earth 
station link at 
1/480
th
 of 
primary data 
rate 
One BW alarm 
EIA-232 Earth 
station link at 
1/480
th
 of 
primary data 
rate 
One BW alarm 
Same as 
EDMAC, plus 
EIA-232 Earth 
station link at 
1/576
th
 of 
primary data 
rate 
EIA-232 
Earth 
station link 
at variable 
rate, plus 
AUPC 
Additional 
Reed-
Solomon 
Overhead 
200/180 
219/201 for 
IESS-310 
mode 
200/180 
T1 = 225/205 
E1 = 219/201 and 
IESS-310 mode 
T2/E2 = 94/178 
126/112 
219/201 for 
IESS-310 mode 
126/112 
219/201 for 
IESS-310 mode 
126/112 126/112 
Scrambling  
 (see 
 Note 1 ) 
Basic ITU 
V.35 
(Intelsat) 
Proprietary 
scrambler 
Basic ITU V.35 
(Intelsat) 
IESS-309 
scrambler 
IESS-309 
scrambler 
Basic ITU 
V.35 (Intelsat) 
Proprietary 
scrambler 
 
Notes:
 
 
1.    Reed-Solomon is Off.  