 Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or included in 
the manual.
2. This product is to be connected to a nominal –48 to –60 VDC supply source that is 
electrically isolated from the AC source using minimum 18 AWG (0.75mm² ) leads . Two 
inputs are provided for redundancy. The positive terminal of the DC source is to be 
reliably connected to earth. Connect a minimum 18 AWG (0.75mm² ) green/yellow 
earthing (grounding) wire to the protective earthing (grounding) screw, identified by the 
protective earth symbol on the back of the chassis.
3. This product may only be used in a Restricted Access Location in accordance with the 
requirements of the National Electric Code, ANSI/NFPA 70, and the Canadian Electrical 
Code, or in accordance with the standards and regulatory requirements of the country in 
which it is installed. A Restricted Access Location is a secure area (dedicated equipment 
rooms, equipment closets, or the like) for equipment where access can only be gained by 
service personnel or by users who have been instructed about the reasons for the 
restrictions applied to the location and about any precautions that must be taken. In 
addition, access into this designated secured area is possible only through the use of a tool 
or lock and key, or other means of security, and is controlled by the authority responsible 
for the location.
4. A readily accessible disconnect device as part of the building installation shall be 
incorporated in fixed wiring. The DC disconnect device must be rated at a minimum 
60 VDC, minimum 2A. The disconnect device shall be readily accessible to the operator. 
The disconnect device must be included with an adequately rated fuse or circuit breaker in 
the ungrounded conductor. Use a minimum 18 AWG (0.75 mm²) fixed power source wires 
with strain retention.
5. Do not allow anything to rest on the power cord and do not locate the product where 
persons will walk on the power cord.
6. Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation 
of the product and to protect it from overheating, these slots and openings must not be 
blocked or covered.
7. Do not attempt to service this product yourself, as it will void the warranty. Opening or 
removing covers may expose you to dangerous high voltage points or other risks. Refer all 
servicing to qualified service personnel.
8. A rare phenomenon can create a voltage potential between the earth grounds of two or 
more buildings. If products installed in separate buildings are interconnected, the voltage 
potential may cause a hazardous condition. Consult a qualified electrical consultant to 
determine whether or not this phenomenon exists and, if necessary, implement corrective 
action prior to interconnecting the products.
9. CLASS 1 LASER PRODUCT: This product has provisions for the customer to install a 
Class 1 laser transceiver, which provides optical coupling to the telecommunication 
network. Once a Class 1 laser product is installed, the equipment is to be considered to be 
a Class 1 Laser Product (Appareil à Laser de Classe 1). The customer is responsible for 
selecting and installing the laser transceiver and for insuring that the Class 1 AEL 
(Allowable Emission Limit) per EN/IEC 60825 is not exceeded after the laser 
!