9.7  Industrial Monitoring Operation 
The  advanced  communication  capabilities  of  the  CTM-130/132  modem  are  designed  for  enabling 
communications  with  remote  industrial  sites.  These  sites  often  operate  equipment  utilizing  industrial 
communication  protocols  such  as  MODBUS  RTU.  The  CTM-130/132  modem  supports  the  MODBUS 
protocol and can be configured for either slave or master connection. In master connection the modem 
performs MODBUS ID to IP mapping.  
 
Base Station
MODBUS Slave devices
MODBUS Master Application
CDMA Netw ork
Chameleon Modem
MODBUS Slaves
Request
Response
UDP encapsulated
MODBUS RTU
messages
Base Station
Chameleon Modem
MODBUS Master
MODBUS RTU
or ASCII
MODBUS RTU
MODBUS ID to
IP address map
 
 
For  other  industrial  protocols  the  PAD  communication  features  of  the  modem  can  be  configured  to 
enable these to be implemented over the CDMA network. 
 
Base Station
Remote Application #1
Local Application
CDMA Netw ork
Chameleon Modem
Internet or Private
Netw ork Group
Request
Response
UDP encapsulated
messages