16-Bit Timer Setup Examples
Panasonic  Semiconductor  Development  Company
MN102H75K/F75K/85K/F85K LSI User Manual
102
Panasonic
P2DIR (example)
x’00FFE2’
To set up timer 0:
1.
Disable timer 0 counting in the timer 0 mode register (TM0MD). This step is 
unnecessary immediately after a reset, since TM0MD resets to 0.
TM0MD (example)
x’00FE20’
2.
Set the divide-by ratio for timer 0. To divide B
OSC
/4 by two, write x’01’ to 
the timer 0 base register (TM0BR). (The valid range for TM0BR is 0 to 
255.)
TM0BR (example)
x’00FE10’
Do not change the clock source 
once you select it. Selecting the 
clock source while you set up 
the count operation control will 
corrupt the value in the binary 
counter.
3.
Set the TM0LD bit of the TM0MD register to 1. This loads the value in the 
base register to the binary counter. At the same time, select the clock source 
as B
OSC
/4 by writing b’00’ to TM0S[1:0].
TM0MD (example)
x’00FE20’
In the bank and linear address-
ing versions of the MN102 
series, it was necessary to set 
TM0EN and TM0LD to 0 
between steps 3 and 4, to 
ensure stable operation. This is 
unnecessary in the high-speed 
linear addressing version.
4.
Set TM0LD to 0 and TM0EN to 1. This starts the timer. Counting begins at 
the start of the next cycle. When the binary counter reaches 0 and loads the 
value x’01’ from the base register, in preparation for the next count, a timer 0 
underflow interrupt request is sent to the CPU.
Bit:
7
6
5
4
3
2
1
0
P2
DIR7
P2
DIR6
P2
DIR5
P2
DIR4
P2
DIR3
P2
DIR2
P2
DIR1
P2
DIR0
Setting:
0
1
1
0
0
0
0
0
Bit:
7
6
5
4
3
2
1
0
TM0
EN
TM0
LD
TM0
S1
TM0
S0
Setting:
0
0
0
0
0
0
Bit:
7
6
5
4
3
2
1
0
TM0
BR7
TM0
BR6
TM0
BR5
TM0
BR4
TM0
BR3
TM0
BR2
TM0
BR1
TM0
BR0
Setting:
0
0
0
0
0
0
0
1
Bit:
7
6
5
4
3
2
1
0
TM0
EN
TM0
LD
TM0
S1
TM0
S0
Setting:
0
1
0
0
0
0
0
0