NTI RACKMUX-V15/17  RACKMOUNT LCD MONITOR WITH KEYBOARD AND MOUSE 
 
3
 
INSTALLATION 
Rack Mounting Instructions 
The RACKMUX was designed to be mounted to a rack and includes mounting flanges to make attachment easy.    
 
1.   Determine the mounting height in the rack for the drawer.    It should be a height comfortable to use the keyboard and see the 
LCD display.  Mark holes in each of the 4 corner cabinet rails at points all level with each other.   
 
2.  Secure the rear brackets to the rear rack cabinet rails.   Apply the top screws (supplied) for each bracket to the holes marked in 
step 1.  
 
3. Lift the keyboard into position and line the studs on the left and right sides up with the slotted openings in the rear bracket.   
Apply the nuts (supplied) to the studs but do not tighten the nuts yet.  
 
FYI:  There are 4 mounting studs provided on each side of the RACKMUX.  Depending on the depth of the rack and 
distance apart of the cabinet rails, the position of the rear bracket may make all 4 studs available for use.    In this case, 
apply the 2 nuts to the studs furthest apart from each other on each side.   
 
4. Slide the drawer in until the top holes in the front bracket flanges line up with the holes marked in step 1.   Secure the front 
brackets on the drawer to the front cabinet rails with two screws per bracket.  Be sure to tighten the screws securely.  Then 
tighten the nuts applied in step 3.     
 
5. Apply one more screw to each of the rear brackets to finish.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                   Figure 1- Mount RACKMUX to a standard rack 
 
Note:   To provide sufficient room for the LCD monitor to be opened to a proper viewing angle (a minimum 90 degree 
position from the keyboard), ensure that all devices mounted  above the RACKMUX extend no more than 1.75” from the 
rack frame.     (See Fig. 2) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                              Figure 2- Position RACKMUX with clearance to open 
 
 
 
Apply nuts (supplied) to studs and 
secure rear brackets to drawer. 
Front bracket
flange on drawer
Rear bracket
   flange
Drawer
Front Cabinet 
      Rail
Rear Cabinet 
      Rail
Rear bracket overlapping
drawer
(Rear edge
of drawer)
Stud on drawer
Secure bracket
to rail using two
 screws and nuts
(supplied)
Secure bracket
to rail using two
 screws and nuts
(supplied)
Side View of RACKMUX
"X" must be
less than 1.75"
for LCD to open
to full 90 
X
90
Server mounted
above RACKMUX 
in the same rack