ATTO Technology V-Class Manuale Utente

Pagina di 117
77
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
 8.0  System Monitoring and Reporting
The Diamond Storage Array provides a number of visual, audible and computer system-generated 
indicators to identify the operational status of the array. System status and error information is readily 
available. 
RS-232 Monitoring Port and CLI 
Use a host 
computer with an RS-232 port and terminal 
emulation software to connect a null modem 
serial cable to the RS-232 port on the array 
management card and control the array via the 
CLI management software built into the array. 
The CLI can be used to configure the unit, modify 
key parameters and read back key system 
information. (refer to 
Accessing the Array 
on page 
17)
Ethernet Monitoring Port and CLI  
If the optional 
Ethernet management system card has been 
installed, use the RJ45 Ethernet port and Telnet to 
access the CLI software on the array. Use the 
same CLI commands to configure, modify or read 
key systems information (refer to 
Accessing the 
Array 
on page 17) or the ExpressNAV browser-
based interface (refer to 
ATTO ExpressNAV: Browser-
based Interface 
on page 25.) If you restart the array, 
the Telnet session ends and the session cannot be 
re-established until the array completes the POST.
Power On Self Test (POST) 
Each time the array 
array is powered up, it performs a series of 
internal tests called POST. The POST sequence 
takes from one to two minutes to complete. 
LEDs blink at various points in the test sequence 
and, if the RS-232 system management port is 
connected, a list of tests and test results scrolls 
across the screen. When the POST is nearly 
complete, all the LEDs on the array flashes 
simultaneously twice. If the system is fully 
operational, the ready LED lights.If the POST 
fails, the System Fault LED lights.
Ready LED 
The Ready LED (RDY) indicates the 
operational status of the array. At power up, a 
green Ready (RDY) LED is disabled until 
successful completion of the POST. 
If a host computer is connected to either a Fibre 
Channel or a SCSI port, the Ready LED blinks, 
then stays lit if the connection is good. If the host 
is rebooted, the Ready LED blinks and stays 
lighted when the connection is reestablished.
Audible Alarm 
The audible alarm beeps twice at 
power up and beeps repeatedly when the System 
Fault (FLT) light on the system management card 
is activated. The alarm turns off when the fault 
condition is cleared or you have disabled the 
alarm by issuing a 
PowerAudibleAlarm
 or 
AudibleAlarm
 command via CLI as described in 
on page 41. Disabling the 
alarm for a specific error does not silence the 
alarm for other errors.
Thermal Monitoring 
The array provides advance 
warning of temperature problems through visual, 
audible and software warning mechanisms and 
through an automatic system which protects the 
disk drives under abnormal conditions.
Temperature sensors provide data to the software 
to trip a temperature warning alarm and, at 
excessively high or low temperatures, flushes 
cache memory to prevent data loss and disables 
disk drive activity to protect the drives. The 
Diamond reports the temperature and the state of 
the warning (
Not Present, OK, Warning, Critica
l) 
through SES, SNMP, CLI and the Status page of 
the ExpressNAV interface. The temperature 
warning alarm reports 
OK
 during normal 
operating conditions.
If an abnormal operating condition, such as 
blower failure, occurs and the array internal 
midplane temperature reaches a critical point, the 
temperature alarm reports 
Warning
 and activates 
the audible alarm and fault LED. If the internal 
midplane temperature reaches a higher point, the 
temperature warming alarm reports 
Critical
, the 
array is taken off line, and all disk drive activity is