ATTO Technology V-Class Manuale Utente

Pagina di 117
86
Hardware maintenance
CAUTION
CAUTION
Do not leave empty openings on the front or rear 
of the array under any circumstances. Empty 
openings affect airflow and may cause the unit to 
overheat and shut down.
Exhibit 9-2: Above, disk drive sled partially pulled out of the Diamond 
Storage Array. Bottom left,  top of disk drive sled. Bottom right, underside 
of disk drive sled showing individual drives 
 
 
Exhibit 9-3: The Fibre Channel or SCSI Host 
Interface C ard  may be replaced by shutting 
power dow n, removing any cable attached to the 
port, removing the SFP according to 
manufacturer's instructions, loosening the 
screws at the top and bottom of the card, then 
carefully pulling out the unit.  
Exhibit 9-4: A power supply pulled out from a rackmount Diamond Storage Array: do not leave an empty opening 
while the Diamond Storage Array is operating. Access the blower assembly and the power supply by loosening the 
screws on either side of the component, then pulling out the part. If a blower or power supply stops working, keep it 
in place until another component is installed. (Note: host interface configuration pictured is not supported)