ATTO Technology SC 7700 Dépliant

Pagina di 2
Rev 9/08 
©2008 ATTO Technology, Inc.  Specifications subject to change without notice. 
Power Behind the Storage 
Technical Specification 
For More Information: 
www.ATTOTech.com 
or to Purchase:      
www.ATTOStore.com
 
(716) 691-1999
 
Technical Features 
 
RAID Levels 
• JBOD, DVRAID, 0, 1, 4, 5, 6, 10, 40, 50 and 60 plus N-way mirroring 
Key Features 
 
Hardware Specifications 
 
Fibre Channel Interface 
• 4-Gigabit, auto-negotiates to 2/1 Gigabit devices 
• Two Optical SFP (Small Form Factor Pluggable) Fibre Channel Host Ports 
• Two Optical SFP Fibre Channel Device Ports 
• Full support for direct connect for F-port fabric switches 
• Class 3 and Intermix ANSI Fibre Channel Specifications 
• PLDA, public loop login (NL-ports) and fabric connect (N-port) 
• Full-duplex transmissions 
Management Interface 
• RJ-45 connector for Ethernet management port 
• RS-232 serial header console port 
Management 
 
Setup and Monitoring 
• Simplified one-click setup allows for system setup in just minutes 
• Built in read-only drive performance monitoring allows you to gauge             
storage performance while host-based applications are in use 
Local and Network Management 
• ExpressNAV
TM
 
storage manager browser-based user interface for remote                
configuration, management and diagnostic capabilities 
• Local diagnostics supported via CLI, Telnet and FTP 
• Command line and menu-based ASCII text management access via the 
Ethernet management port 
Environmental & Physical Specifications 
 
Dimensions 
• 1.69” (1U) H x 17.31” W x 9.9” L 
Operating Environment 
• Temperature: 5 - 40° C 
● 
Humidity: 10 - 90% non-condensing 
Storage Environment 
• Temperature: -40 - 70° C 
 Humidity: 5 - 95% non-condensing 
Power 
• Input: 100-240 VAC, 2.5A, 47-63 Hz 
Airflow 
• 11 CFM recommended 
• Ambient air not to exceed 40° C 
RoHS Compliant 
• Yes 
Ordering Information 
 
Model Number 
FSSC-7700-D00 
FastStream™ SC 7700 
Storage Controller 
FastStream SC 7700 
• Tunable RAID Rebuild Priority 
• SCSI Enclosure Services (SES) 
• Real-time Performance Metrics 
• Configurable Sector Sizes to 8KB 
• Application Performance Reporting  • Field Upgradeable Firmware 
• Local and Global Hot Spares 
• Hot Swap with Auto Rebuild 
• Configuration Cloning 
• Battery Backed Event Log 
• Drive Initialization and Verification  • ECC Protected Memory 
• Partitioning of RAID Volumes 
• Advanced Error Handling 
• Port Mapping for LUN Isolation 
• One button setups for Audio, Video, IT