Compaq Infortrend Manuale Utente
Infortrend
8-10
1. Fibre Channel Connection Type:
Use the
↑↑↑↑
↓↓↓↓
keys to scroll down to “View and Edit Configuration
Parameters,” "Host-side SCSI Parameters," and then "Fibre
Connection Option." A prompt will display all the options. Select
one appropriate for your Fibre channel topology. If connection to
host is through a Fibre hub, choose "Loop only."
Connection Option." A prompt will display all the options. Select
one appropriate for your Fibre channel topology. If connection to
host is through a Fibre hub, choose "Loop only."
If connection to host is through a Fibre switch F_Port or directly to a
server, choose "Point to point only." Proper selection is necessary
and will decrease overhead on data transmission.
server, choose "Point to point only." Proper selection is necessary
and will decrease overhead on data transmission.
A redundant controller configuration should always have its host
connection configured in FC-AL mode. For a switched fabric
configuration, a redundant controller system can be connected to the
FL_ports on an FC switch and then the host computers connect to its
F_ports.
connection configured in FC-AL mode. For a switched fabric
configuration, a redundant controller system can be connected to the
FL_ports on an FC switch and then the host computers connect to its
F_ports.
View and Edit Drive-Side Parameters
2. Drive-Side Dual Loop:
Fibre drives are usually configured in a JBOD enclosure. Through
the enclosure backplane, these drives form one or two circuit loops.
You may choose to assemble certain number of disk drives into a
dual-loop configuration using two of the controller channels.
the enclosure backplane, these drives form one or two circuit loops.
You may choose to assemble certain number of disk drives into a
dual-loop configuration using two of the controller channels.
To configure a dual-loop, connect two of the drive channels each to
an FC-AL port on the drive enclosure (JBOD). Please refer to the
related documents that came with your drive enclosure for the
connection details.
an FC-AL port on the drive enclosure (JBOD). Please refer to the
related documents that came with your drive enclosure for the
connection details.
The dual-loop configuration not only doubles traffic bandwidth by
separating the transmitting and receiving paths but also provides
path redundancy. I/O traffic will be continued should one data
path fail.
separating the transmitting and receiving paths but also provides
path redundancy. I/O traffic will be continued should one data
path fail.