10.2 Preparing Controllers 
10.2.1 Requirements:
Cabling Requirements:
Communications Channels:
Controller Communications (Cache Synchronization) Paths:
Controller
RCC cable
SentinelRAID
A SCSI cable (CH 0)
EonRAID 2510FR
Dedicated RCC or RCC over drive loops
EonStor
Pre-configured RCC routes over the system
backplane
Using one or two of the I/O channels for controller communications
(as listed above) is necessary especially when write-back caching is
preferred.  If controllers are running in write-back mode, a battery
module is recommended for each controller.
Use the default channel (CH 0) for the SentinelRAID controllers.   
Out-of-Band Configuration
RS-232C cable (for Terminal Interface Operation) connection.
Ethernet connection: If management through Ethernet is preferred,
connect the Ethernet interface from both controllers to ports on a hub.
The IP address assigned to one controller will be inherited by the
surviving controller.
Host and Drive Connection

All channels on one controller must be connected to the same channels
on its counterpart.