Compaq Infortrend Manuale Utente
Infortrend
10-20
10.3.1 Via Front Panel Keypad
Redundant Configuration Using Automatic Setting
Power-on Controller 1. Make sure Controller 2 is powered-off.
1. Enable Redundant Controller
Press [ENT] for two seconds on the front panel of
controller 1 to enter the main menu. Use ▼ or ▲
to navigate through the menus. Choose "View
and Edit Peripheral Dev.. (View and Edit
Peripheral Devices)," then press [ENT].
controller 1 to enter the main menu. Use ▼ or ▲
to navigate through the menus. Choose "View
and Edit Peripheral Dev.. (View and Edit
Peripheral Devices)," then press [ENT].
Choose "Set Peripheral Devices Entry," then press
[ENT].
[ENT].
Choose "Redundant Ctlr Function__", and then
press [ENT]. (Note: The current setting will be
displayed on the LCD) If this controller has never
been set as a redundant controller before, the
default setting of the redundant controller
function is "Disabled." The message "Redundant
Ctlr Function Disable" will be displayed on the
LCD. Press [ENT] to proceed.
press [ENT]. (Note: The current setting will be
displayed on the LCD) If this controller has never
been set as a redundant controller before, the
default setting of the redundant controller
function is "Disabled." The message "Redundant
Ctlr Function Disable" will be displayed on the
LCD. Press [ENT] to proceed.
Autoconfig.
The message "Enable Redundant Ctlr: Autocfg?"
will appear. Use ▼ or ▲ to scroll through the
available options ("Primary," "Secondary," or
"Autocfg"), then press [ENT] for two seconds to
select "Autocfg."
will appear. Use ▼ or ▲ to scroll through the
available options ("Primary," "Secondary," or
"Autocfg"), then press [ENT] for two seconds to
select "Autocfg."
For the other controller is currently not
connected, status will be indicated as “Inactive.”
Once set, press [ESC] for several times to return
to the main menu.
connected, status will be indicated as “Inactive.”
Once set, press [ESC] for several times to return
to the main menu.
2. Controller Unique ID
Enter “View and Edit Config Parms”->
“Controller Parameters”. Use ▼ or ▲ to find
“Ctlr Unique ID- xxxxx”.
“Controller Parameters”. Use ▼ or ▲ to find
“Ctlr Unique ID- xxxxx”.
This value will be used to generate a controller-
unique WWN node name and port names and to
identify the controller during the failover process.
Enter a hex number from 0 to FFFFF and press
[ENTER]. The value you enter should be
different for each controller.
unique WWN node name and port names and to
identify the controller during the failover process.
Enter a hex number from 0 to FFFFF and press
[ENTER]. The value you enter should be
different for each controller.
View and Edit
Peripheral Dev
Peripheral Dev
Set Peripheral
Devices Entry
Devices Entry
Redundant Ctlr
Function Disable
Function Disable
Enable Redundant
Ctlr: Autocfg ?
Ctlr: Autocfg ?
Ctlr Unique
ID- 00012 ?
ID- 00012 ?
Redundant Ctlr:
Autocfg Inactive
Autocfg Inactive
View and Edit
Config Parms
Config Parms
Controller
Parameters ..
Parameters ..