10.3.1 Via Front Panel Keypad
Redundant Configuration Using Automatic Setting
Power-on Controller 1.  Make sure Controller 2 is powered-off.
1.  Enable Redundant Controller
Press [ENT] for two seconds on the front panel of
controller 1 to enter the main menu.  Use ▼ or ▲
to navigate through the menus.  Choose "View
and Edit Peripheral Dev.. (View and Edit
Peripheral Devices)," then press [ENT].
Choose "Set Peripheral Devices Entry," then press
[ENT].
Choose "Redundant Ctlr Function__", and then
press  [ENT].  (Note: The current setting will be
displayed on the LCD)  If this controller has never
been set as a redundant controller before, the
default setting of the redundant controller
function is "Disabled."  The message "Redundant
Ctlr Function Disable" will be displayed on the
LCD.  Press [ENT] to proceed.
Autoconfig.
The message "Enable Redundant Ctlr: Autocfg?"
will appear.  Use ▼ or ▲ to scroll through the
available options ("Primary,"  "Secondary,"  or
"Autocfg"), then press [ENT] for two seconds to
select "Autocfg."
For the other controller is currently not
connected, status will be indicated as “Inactive.”
Once set, press [ESC]  for several times to return
to the main menu.
2.  Controller Unique ID
Enter “View and Edit Config Parms”->
“Controller Parameters”.  Use ▼ or ▲ to find
“Ctlr Unique ID- xxxxx”.
This value will be used to generate a controller-
unique WWN node name and port names and to
identify the controller during the failover process.
Enter a hex number from 0 to FFFFF and press
[ENTER].  The value you enter should be
different for each controller.
View and Edit
Peripheral Dev
Set Peripheral
Devices Entry
Redundant Ctlr
Function Disable
Enable Redundant
Ctlr: Autocfg  ?
Ctlr  Unique
ID- 00012     ?
Redundant Ctlr:
Autocfg Inactive
View and Edit
Config Parms
Controller
Parameters   ..