from the original members to larger drives, and then the smaller
drives can be replaced without powering down the system.
 
Note on Expansion
 
1.  Added Capacity:
When a new drive is added to an existing logical drive, the
capacity brought by the new drive appears as a new partition.
Assuming that you have 4 physical drives (each of the size of
36GB) in a logical drive, and that each drive’s miximum capacity
is used, you will have a logical drive of the size of 108GB.  One
drive’s capacity is used for parity; e.g., RAID 3.  A 36GB drive is
added, the capacity will be increased to 144GB in two separate
partitions (one is 108GB and the other 36GB).
2.  Size of the New Drive:
A drive used for adding the capacity should have the same
capacity as that of the array’s members.
3.  Applicable Arrays:
Expansion can only be performed on RAID 0, 3, and 5 logical
drives.  Expansion can not be performed on a logical
configurations that do not have parity; e.g., NRAID or RAID 1.
NOTE:
 
Expansion on RAID0 is not recommended, because the RAID0 array has
no redundancy.  Interruptions during the expansion process may cause
unrecoverable data loss.
4.  Interruption to the Process:
Expansion should not be canceled or interrupted once begun.  A
manual restart should be conducted after the occurrence of
power failure or interruption of any kind.