Compaq Infortrend Manuale Utente

Pagina di 347
Infortrend
1-9
1.6
Rebuild
Automatic Rebuild and Manual Rebuild
1.  Automatic Rebuild
Figure 1 - 13 Automatic Rebuild
Rebuild with Spare:
  When a member drive in a logical drive
fails, the controller will first examine whether there is a Local Spare
Drive assigned to this logical drive.  If yes, rebuild is automatically
started.
If there is no Local Spare available, the controller will search for a
Global Spare.  If there is a Global Spare, rebuild automatically
begins using the Global Spare.
Failed Drive Swap Detect:
 If neither Local Spare Drive nor
Global Spare Drive is available, and the "Periodic Auto-Detect
Failure Drive Swap Check Time
" is "Disabled," the controller will not
attempt to rebuild unless the user applies a forced-manual rebuild.
When the "Periodic Auto-Detect Failure Drive Swap Check Time" is
"Enabled" (i.e., a check time interval has been selected), the
controller will detect whether a faulty drive has been swapped (by
checking the failed drive's channel/ID).  Once the failed drive has
been replaced by a healthy drive, the rebuild will begin
immediately.
One member drive 
fails in logical drive
Any 
local spare drive
assigned to logical
drive?
Any 
global spare drive
assigned to logical
drive?
“Periodic 
Auto-Detect Failure
Drive Swap Check Time”
enabled?
Has the
failed drive been
swapped?
Waiting for spare
drive to be added
or manual rebuild
Rebuild using the
swapped drive
Rebuild using the
local spare drive
Rebuild using the
global spare drive
Keep detecting if drive
 has been swapped or
spare drive has been
added
No
Yes
No
No
Yes
No
Yes
Yes