 Troubleshooting
9-7
Warnings
Warning events let you know that something related to the controller or an array has a 
problem. You should correct the problem as soon as possible. Table 9-1 below 
defines each warning event and recommends the action you should take.
Table 9-1. Warning events
Event
Definition
Recommended Action
BATT FAIL INFO
A warning condition in the 
battery pack and/or charging 
interface has been detected.
Replace the battery. Refer to the 
enclosure’s documentation.
REPLACE 
BATTERY
The battery is approaching its 
3-year life span.
Replace the battery.
ARRAY 
CRITICAL
One or more drives were 
downed and the array is online 
but no longer fault tolerant.
Add a spare to the array or to the 
spare pool. Then replace the bad 
drives. See Adding a Dedicated 
Spare
 on page 6-2
 or Adding a 
Spare to the Spare Pool
 on 
page 6-5
.
DRIVE DOWN
An error occurred with the 
drive and it was downed, 
removing it from the active 
array.
Add a spare to the array or to the 
spare pool. Then replace the bad 
drive. SeAdding a Dedicated 
Spare
 on page 6-2
 or Adding a 
Spare to the Spare Pool
 on 
page 6-5
.
SPARE 
UNUSABLE
The drive still contains 
metadata that must be cleared.
Clear the metadata from the spare 
drive. SeClearing Metadata 
from a Drive
 on page 8-4.
SMART EVENT
A disk drive IEPC 
(informational exceptions page 
control) predictive failure 
message was received. No 
actions by the controller are 
taken on the drive for these 
events.
Run diagnostics available from 
your operating system on the 
affected drive. Replace the drive, 
if necessary.