Inserting the 3C319 NIC
2-3
3 Remove the 3C319 NIC from its antistatic container.
4 Inspect the 3C319 NIC for visible signs of damage.
If you find a problem, immediately notify your authorized 
network supplier and the carrier that delivered the NIC.
Complete the Product Registration Card and return 
it to 3Com. Or call 1-800-NET-3Com for immediate 
registration.
Inserting the 3C319 NIC
Follow these steps to insert the 3C319 NIC:
1 Insert the 3C319 NIC in an empty ISA or EISA 
expansion slot.
Make sure it is completely seated in the slot by pushing 
down firmly on both ends of the NIC.
2 Connect one of the following network cable types 
to the 3C319 NIC:
Shielded twisted-pair (STP) cable with a 
DB-9 connector
Unshielded twisted-pair (UTP) cable with an 
RJ-45 connector
CAUTION: Connect the cable only to the 3C319 NIC 
that you have just installed. Connecting the cable to 
other NICs could cause serious damage to them and 
the token ring network.
TokenLink Velocity NICs support industry-standard token 
ring Category 3, 4 or 5 UTP or types 1 or 6 STP cabling. 
These cables meet IEEE 802.5 specifications.
Do not daisy-chain token ring NICs or connect them 
back to back.