Nortel Networks NN43011-110 Manuale Utente

Pagina di 48
Description
21
Figure 4
Circuit card assignments in the Chassis Expander
The following is an example of a common Main Chassis configuration:
one SSC card in slot 0
one analog line card in slot 1, 2, or 3
one digital trunk card in slot 1, 2, or 3
one analog trunk card in slot 1, 2, or 3
one NTDK16, 48-port Digital Line Card in slot 4
The following is an example of a common Chassis Expander configuration:
line cards in slots 7, 8, and 9
Meridian Mail in slot 10
Power
The Universal Power Supply (UPS) unit is installed in the Chassis before it
is sent to the customer and requires no installation by the customer. The
power supply operates on standard line voltages of 100–240 V AC. Total
output power is 363 Watts.
Note: The Chassis system does not support DC power input.
A UPS can provide reserve AC power. The Chassis system does not
support battery backup.
Nortel Communication Server 1000
Communication Server 1000M and Meridian 1 Small System Overview
NN43011-110
01.01
Standard
Release 5.0
30 May 2007
Copyright © 2003 - 2007, Nortel Networks
.