Nortel Networks NN44200-300 Manuale Utente
48
Chapter 5 Installing the server and connecting the peripheral devices
2
Plug the keyboard/mouse dual cable into the PS/2 connector on the
SBC card faceplate (see
SBC card faceplate (see
).
3
Plug the keyboard and mouse into the appropriate connectors on
the keyboard/mouse dual cable.
the keyboard/mouse dual cable.
4
Plug the monitor into the monitor connector on the SBC card.
Tighten the screws on the connector.
Tighten the screws on the connector.
5
Ensure that a single-point ground reference is available for all
the power outlets serving the CallPilot server and its peripherals.
Before the CallPilot server installation, a qualified electrician must
implement the single-point ground reference requirement between
the power outlets of the CallPilot server and the power outlets of
the switch.
the power outlets serving the CallPilot server and its peripherals.
Before the CallPilot server installation, a qualified electrician must
implement the single-point ground reference requirement between
the power outlets of the CallPilot server and the power outlets of
the switch.
6
Connect the power cord to the monitor and plug the other end into
a wall receptacle or power bar.
a wall receptacle or power bar.
Note: Ensure that the power source is consistent with the SBC
for all ancillary equipment.
for all ancillary equipment.
7
Turn on the monitor.
—End—
To connect the modem to the server
Step
Action
1
Ensure that the modem AC power cord is not plugged in.
2
Connect the large 25-pin male connector to the back of the modem.
Tighten the connector screws.
Tighten the connector screws.
3
Connect the 9-pin female connector to COM1 at the rear of the
server. Tighten the connector screws.
server. Tighten the connector screws.
4
Connect one end of the telephone cable to the modem RJ-11 jack
labeled LINE.
labeled LINE.
5
Connect the other end of the telephone cable to the RJ-11 jack in
the wall.
the wall.
6
Ensure that a single-point ground reference is available for all
the power outlets serving the CallPilot server and its peripherals.
Before the CallPilot server installation, a qualified electrician must
implement the single-point ground reference requirement between
the power outlets serving the CallPilot server and its peripherals.
Before the CallPilot server installation, a qualified electrician must
implement the single-point ground reference requirement between
Nortel CallPilot
1002rp Server Hardware Installation
NN44200-300
01.01
Standard
5.0
23 February 2007
Copyright © 2007, Nortel Networks
Nortel Networks Confidential
.