Chapter 4 Installing the R2MFC MBM 33
R2MFC Media Bay Module Installation and Configuration Guide
Click Ok.
The progress update dialog box appears and the BCM system begins the shutdown 
process. When the shutdown process is complete, the final warning dialog box appears, 
and the LEDs enter the flashing state.
Click Ok to disconnect Element Manager.
When the shutdown Element Manager is disconnected, the system gives an audible beep. 
The LEDs remain in the flashing state until the hardware is shutdown (see 
).
If the system hardware is not shutdown within about 15 minutes, it automatically boots up 
again.
Shutting down the BCM 4.0 system hardware
Remove the DS256 cables from the front of the BCM main unit and, if present, the expansion 
unit. This includes the data connections on the MSC.
Mark the cables to ensure correct reconnection.
Turn off the power switch located on the BCM main unit and expansion unit.
Disconnect the BCM main unit and expansion unit power cords from the AC outlet.
Ensure you have room to access the part you are working on. Remove the BCM main unit 
from the rack, if necessary.
Shutting down a BCM 3.7 or lower system
If you are adding or replacing an R2MFC MBM in an active system, perform the following 
steps:
Access the Unified Manager.
Choose System.
Select the Logoff menu and then click Shutdown.
Click Yes.
Warning: Remove all of the connections to the BCM system before you 
power down the system.
Failure to disconnect lines before you power down the system can cause 
damage to the system.
Warning: You must disconnect power from the main unit after you 
have performed an Element Manager shutdown. The main unit cannot 
start operating again until after power has been disconnected and then 
reconnected.