Nortel Networks R2MFC Manuale Utente

Pagina di 114
Configuring DIP switch settings and definitions 93
R2MFC Media Bay Module Installation and Configuration Guide
Country code defaults
This section contains the default configuration associated to the country code set by the DIP 
switches on the faceplate of the R2MFC MBM.
Mexico Config 1
E1 physical characteristics
Connector type: BNC
Line coding: HDB3
E1 framing
Frame mode: Alternate
Register signaling
Regret option: OFF
End of dialing (Incoming): terminated by indication from destination switch, or by MFC 
forward signal FW_EndDigits
End of dialing (Outgoing): terminated by indication from destination switch, or by MFC 
forward signal FW_EndDigits
R2 line signaling
Mexico Config 1 R2 signals are according to CCITT standard. See 
1 R2 signal definitions.  
Note: CD bits are not used. They are set to 01 in transmit direction, and are ignored in receive direction.
Table 28   Mexico Config 1 R2 A/B signals
Forward
Backward
Signal
A
B
Signal
A
B
Idle
1
0
Idle
1
0
Seize
0
0
Seize acknowledge
1
1
Clear forward
1
0
Answer
0
1
Clear back
1
1
Block
1
1