Nortel Networks R2MFC Manuale Utente
Configuring DIP switch settings and definitions 93
R2MFC Media Bay Module Installation and Configuration Guide
Country code defaults
This section contains the default configuration associated to the country code set by the DIP
switches on the faceplate of the R2MFC MBM.
switches on the faceplate of the R2MFC MBM.
Mexico Config 1
E1 physical characteristics
•
Connector type: BNC
•
Line coding: HDB3
E1 framing
Frame mode: Alternate
Register signaling
•
Regret option: OFF
•
End of dialing (Incoming): terminated by indication from destination switch, or by MFC
forward signal FW_EndDigits
forward signal FW_EndDigits
•
End of dialing (Outgoing): terminated by indication from destination switch, or by MFC
forward signal FW_EndDigits
forward signal FW_EndDigits
R2 line signaling
1 R2 signal definitions.
Note: CD bits are not used. They are set to 01 in transmit direction, and are ignored in receive direction.
Table 28 Mexico Config 1 R2 A/B signals
Forward
Backward
Signal
A
B
Signal
A
B
Idle
1
0
Idle
1
0
Seize
0
0
Seize acknowledge
1
1
Clear forward
1
0
Answer
0
1
Clear back
1
1
Block
1
1