Chapter 14 — Installing Power Failure
Transfer Units
This chapter describes how to install a QUA6 Power Failure Transfer Unit 
(PFTU). This chapter contains the following procedure:
You can connect PFTUs to the Main Chassis.
Note: The QUA6 PFTU operates with loop start and ground start CO 
trunks. With ground start trunks, the associated telephone set must have 
a ground start button.
If you require power failure backup as a fail safe for this system, use analog 
trunks. A PFTU does not support digital trunks. 
Installing the PFTU
Refer to the equipment layout plan to determine where to locate the PFTU. 
See “Chapter 4 — Creating an equipment layout plan and a card slot 
assignment plan” on page 69.
Procedure 23
Installing the PFTU
1
Install the PFTU on the wall near the system cross-connect 
terminal. Fasten the PFTU in position
 
with four screws.
2
Install an NE-A25B-type 25-pair cable from connector J1 on the 
faceplate of the PFTU to its assigned location at the 
cross-connect terminal.
3
Label the pairs of the J1 cable on the cross-connect terminal 
block as shown in Figure 56 on page 186.