Planning and Installation Guide
Figure 9
Typical layout for installing the chassis on a wall in a horizontal position
Note: Leave wall space for the cross-connect terminal.
7
8
9
10
Power
Fan
NETW
ORKS
7
8
9
10
Power
Fan
NETW
ORKS
Main 
Chassis
Chassis 
Expander
Maximum of 
21 in. (533 mm)
Minimum of 
12 in. (305 mm)
Draw 2 vertical lines 
18.5 in. (470 mm)apart
Each chassis measures
8.4 in. x 17.2 in. x 12.8 in.
(213 mm x 437 mm x 325 mm) 
Distance from 
edge of backboard 
to isolated 
ground outlet 
0 - 27 in. (686 mm)
Leave at least 
2 in. (51 mm) 
between edge 
of backboard 
and corner of room
Allow 24 in. (610 mm) at the top 
for miscellaneous equipment
Draw horizontal line
for bottom hole of 
ear bracket
10 in. (254 mm)
Recommended lowest position 
for chassis installation is 
10 in. (254 mm) from floor
12 in. (305 mm)