ROUBLESHOOTING
A-2
© 2003 Foundry Networks, Inc.
February 2003
check for loose power connections, power losses or surges at the power 
outlet, and verify that the fans on the unit are unobstructed and running 
prior to shutdown. If you still cannot isolate the problem, then the internal 
power supply may be defective. In this case, contact Technical Support for 
assistance.
Installation
Verify that all system components have been properly installed. If one or 
more components appear to be malfunctioning (such as the power cord or 
network cabling), test them in an alternate environment where you are sure 
that all the other components are functioning properly.
In-Band Access
You can access the management agent in the switch from anywhere within 
the attached network using Telnet, a Web browser, or other network 
management software. However, you must first configure the switch with a 
valid IP address, subnet mask, and default gateway. If you have trouble 
establishing a link to the management agent, check to see if you have a 
valid network connection. Then verify that you entered the correct IP 
address. Also, be sure the port through which you are connecting to the 
switch has not been disabled. If it has not been disabled, then check the 
network cabling that runs between your remote location and the switch.
Note: The management agent can accept up to four simultaneous Telnet 
sessions. If the maximum number of sessions already exists, an 
additional Telnet connection will not be able to log into the 
system.