Finisar Surveyor Manuale Utente

Pagina di 454
3-20
Surveyor 
User’s Guide
Establishing Links for THGm 
The THGm is often connected to a device that cannot auto negotiate the connection, 
such as when monitoring/analyzing a connection through a tap device. The device 
will automatically go through a sequence of attempts to disable auto negotiation and 
establish a link with a device that cannot auto negotiate. However, if a link cannot 
be automatically established with a device, you can attempt to establish a link 
manually by disabling auto negotiation mode. The 
Fiber Link
 option from the 
Module 
menu allows you to disable auto negotiation and alert the module to begin 
listening for data. Make sure the 
No Auto Negotiation
 item is selected from the menu. 
Auto negotiation enabled is the default value.
The 
Module
 menu also has a 
Fiber Link 
 Link Status
 option which provides 
information about a 1000 Mbps link. If the carrier wave is present, this option 
returns a “link OK” message. If there is a problem with the link, a message screen 
appears with diagnostic information that may help you troubleshoot the link. 
The “link OK” message is returned if the device can sense the carrier wave on its 
receive port. However, if a THGm has a proper physical connection to a device that 
cannot auto negotiate the connection, this option will report that the link is OK even 
though the devices do not recognize each other. The 
Link Status
 option is of limited 
use when connecting to devices such as taps where the problem is an auto 
negotiation failure.