Chapter 7 Buffer read/write instructions
7 - 10
2) Program example
- Program that write 10 words, through the Fnet module mounted at the slot 02, from the
D0200 ~ D0209 of self station to the address 11~20 of the buffer memory of the G3F-
AD3A module mounted at the slot 02 of remote station h0E. The link status will be stored
at M020 of self station.
[ System configuration ]
Self-station
GM4-
PA2A
K4P-
15AS
G4I-
D22A
G4I-
D22A
G4L-
FUEA
Station
No=h01
No=h01
G4L-
FUEA
Station
No=h02
No=h02
G4Q-
RY2A
slot 0
slot 1
slot 2
slot 3
slot 4
Remote station
GM3-
PA2A
G3L-
RBEA
Station
No=h0E
G3I-
D22A
G3Q-
RY2A
RY2A
G3F-
AD3A
slot 0
slot 1
slot 2
[ Example program ]
‘sl’ :
upper byte
à the code of remote module is hC0
lower byte
à slot number of Fnet module of self station is h02
‘st’ :
upper byte
à slot number of remote A/D module is h02
lower byte
à the station number of remote station is h0E
RPUT hC002 h020E D0200 00011 0010 M020
Input
condition